| Electronic Components Datasheet Search |
|
OVA5000 Datasheet(PDF) 2 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
OVA5000 Datasheet(HTML) 2 Page - List of Unclassifed Manufacturers |
|
2 / 2 page ![]() Optical Vector AnalyzerTM is a trademark of Luna Innovations Incorporated. ©Luna Innovations Incorporated, Roanoke, VA All rights reserved. OVA 5000 LT0VA5000 REV. 005 02/13/2014 PARAMETER FAST MODE* AVERAGING MODE* UNITS Wavelength Range: 1270-1340 or 1525-1610 nm Wavelength: Standard Resolution 1.6 1.6 pm Accuracy1 ±1.5 ±1.5 pm Repeatability ±0.1 ±0.1 pm Optical Phase Error: ±0.05 ±0.0075 radians Loss Characteristics: Dynamic range2 60 80 dB Ripple ±0.05 ±0.01 dB Resolution ±0.05 ±0.002 dB Insertion loss accuracy ±0.1 ±0.05 dB Return loss accuracy ±0.2 ±0.1 dB Chromatic Dispersion: Accuracy ±10 ±5 ps/nm Group Delay: Range3 6 6 ns Accuracy ±0.2 ±0.1 ps Loss range2 45 60 dB PMD: Range3 6 6 ns Accuracy – First Order ±0.03 (100pm steps) ±0.15 (30pm steps) ±0.08 ps Accuracy – Second Order ±10 ±2 ps2 Loss range2 40 50 dB PDL: Extinction ratio 40 50 dB Accuracy ±0.05 ±0.03 dB Measurement Timing: Laser sweep rate 70 70 nm/s All-parameter measurement rate4 30 30 ms/nm Fully specified measurement time5 12 55 s Real-time mode update rate6 1 NA Hz Maximum Device Length (including leads): Transmission 150 150 meters Reflection 75 75 meters Physical Weight (Processor not Included) 16.24 35.8 kg lbs Case Size (W X D X H) 473 X 420 X 206 18.62 X 16.54 X 8.08 mm inches 1 Accuracy maintained by an internal NIST-traceable HCN gas cell. 2 8 0, 60 and 50 dB dynamic ranges in ‘Averaging Mode’ for IL, GD and PMD are with the “High Dynamic Range Averaging” option installed and enabled. 3 Specifies the total device impulse-response duration that may be captured. 4 Rate calculated from combined laser sweep and analysis time per scan. 5 Measurement with full specification (see note 2) over Fast Mode: 40 nm range, and Averaging Mode: 2.5 nm range. Excludes calibration time. 6 For 2.5 nm scan range. Fast Mode: no averaged calibration scans, 4 averaged measurement scans, 30 pm resolution bandwidth, 8 m device length (accuracies verified using NIST certified artifacts except for IL). High dynamic range option enabled. Averaging Mode: 4 averaged calibration scans, 64 averaged measurement scans, 30 pm resolution bandwidth, 8 m device length (accuracies verified using NIST certified artifacts except for IL). High dynamic range option enabled. *results are typical CLASS 1 LASER PRODUCT |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |