| Electronic Components Datasheet Search |
|
CS10.243 Datasheet(PDF) 21 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CS10.243 Datasheet(HTML) 21 Page - PULS GmbH |
|
21 / 25 page ![]() CS10.243 C-Line 24V, 10A, SINGLE PHASE INPUT 22. APPLICATION NOTES 22.1. PEAK CURRENT CAPABILITY The unit can deliver peak currents (up to several milliseconds) which are higher than the specified short term currents. This helps to start current demanding loads. Solenoids, contactors and pneumatic modules often have a steady state coil and a pick-up coil. The inrush current demand of the pick-up coil is several times higher than the steady-state current and usually exceeds the nominal output current (including the PowerBoost). The same situation applies when starting a capacitive load. The peak current capability also ensures the safe operation of subsequent circuit breakers of load circuits. The load branches are often individually protected with circuit breakers or fuses. In case of a short or an overload in one branch circuit, the fuse or circuit breaker need a certain amount of over-current to open in a timely manner. This avoids voltage loss in adjacent circuits. The extra current (peak current) is supplied by the power converter and the built-in large sized output capacitors of the power supply. The capacitors get discharged during such an event, which causes a voltage dip on the output. The following two examples show typical voltage dips: Fig. 22-1 Peak load with 2x the nominal current for 50ms, typ. Fig. 22-2 Peak load with 5x the nominal current for 5ms, typ. 10ms/DIV Output Voltage Output Current 24V 0A 20A 18.5V 1ms/DIV Output Voltage Output Current 24V 0A 50A 12V 20A Peak load (resistive) for 50ms Output voltage dips from 24V to 18.5V. 50A Peak load (resistive) for 5ms Output voltage dips from 24V to 12V. Peak current voltage dips typ. from 24V to 18.5V at 20A for 50ms, resistive load typ. from 24V to 17V at 50A for 2ms, resistive load typ. from 24V to 12V at 50A for 5ms, resistive load Jul. 2015 / Rev. 2.0 DS-CS10.243-EN All parameters are specified at 24V, 10A, 120Vac, 60Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 21/25 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |