| Electronic Components Datasheet Search |
|
CP10.242-R2 Datasheet(PDF) 19 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CP10.242-R2 Datasheet(HTML) 19 Page - PULS GmbH |
|
19 / 31 page ![]() CP10.241-R1, CP10.241-R2, CP10.241-R3,CP10.242-R2 CP-Series 24V, 10A, 240W, SINGLE PHASE Feb. 2018 / CP10.241-R2 Rev0.3-EN - All values are typical figures specified at 230Vac, 50Hz input voltage, 24V, 10A output load, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 19/31 P R E L I M I N A R Y 18. SAFETY AND PROTECTION FEATURES Isolation resistance Min. 500MOhm At delivered condition between input and output, measured with 500Vdc Min. 500MOhm At delivered condition between input and PE, measured with 500Vdc Min. 500MOhm At delivered condition between output and PE, measured with 500Vdc Min. 500MOhm At delivered condition between output and DC-OK contacts, measured with 500Vdc PE resistance Max. 0.1Ohm Resistance between PE terminal and the housing in the area of the DIN-rail mounting bracket. Output over-voltage protection1) Typ. 30.5Vdc Max. 32Vdc Class of protection I According to IEC 61140 Degree of protection IP 20 According to EN/IEC 60529 Over-temperature protection2) Included Output shut-down with automatic restart. Input transient protection MOV (Metal Oxide Varistor) For protection values see chapter 16 (EMC). Internal input fuse Included Not user replaceable slow-blow high-braking capacity fuse Touch current (leakage current) Typ. 0.14mA / 0.36mA At 100Vac, 50Hz, TN-,TT-mains / IT-mains Typ. 0.20mA / 0.50mA At 120Vac, 60Hz, TN-,TT-mains / IT-mains Typ. 0.33mA / 0.86mA At 230Vac, 50Hz, TN-,TT-mains / IT-mains Max. 0.18mA / 0.43mA At 110Vac, 50Hz, TN-,TT-mains / IT-mains Max. 0.26mA / 0.61mA At 132Vac, 60Hz, TN-,TT-mains / IT-mains Max. 0.44mA / 1.05mA At 264Vac, 50Hz, TN-,TT-mains / IT-mains 1) In case of an internal defect, a redundant circuit limits the maximum output voltage. The output shuts down and automatically attempts to restart. 2) Temperature sensors are installed on critical components inside the unit and turn the unit off in safety critical situations, which can happen e.g. when ambient temperature is too high, ventilation is obstructed or the de-rating requirements are not followed. There is no correlation between the operating temperature and turn-off temperature since this is dependent on input voltage, load and installation methods. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |