| Electronic Components Datasheet Search |
|
FS-V21 Datasheet(PDF) 4 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
FS-V21 Datasheet(HTML) 4 Page - List of Unclassifed Manufacturers |
|
4 / 4 page ![]() 4 9. Key Lock The key lock function disables the operation of all keys. Indicates that the keys are locked. Press the manual button for three seconds while pressing the mode button. • Take the same step to unlock the keys. 10. Mode Settings before Shipping (Initialization) The following factory settings are made before shipping. EASY FINE OFF Light-ON Access mode Power mode Timer function Output selection * Returning to factory settings: Press the button for a minimum of five seconds while pressing the button. 11. Hints On Correct Use • To extend the cable length, use a cable with at least a 0.3 mm2 cross- section area. Limit the length of cable extension to no more than 100 m. (To connect several units, contact Keyence for further information.) • Do not wire the amplifier line along with power lines or high-tension lines, or otherwise the sensor may malfunction or receive damage due to noise. • When using a commercially available switching regulator, ground the frame ground terminal and ground terminal. • Do not use the FS series outdoors, or in a place where extraneous light can enter the light receiving surface directly. • Due to the individual dispersion of characteristics and the difference in fiber unit model, the maximum sensing distance or displayed value of all the units are not the same. • If the sensor is used in S-APC mode for a long time, the LED indicators will be imposed with a heavy load. In that case, the sensor will be auto- matically set to ACC mode where the current consumption of the sen- sor for light emission will be constant, and “END APC” will be displayed. The sensor can be continuously used in this case. Replace the sensor, however, if highly precise detection is required. 12. Specifications Model Light source Response time Display shift function Timer function Control output Supply voltage Current consumption Ambient illumination Ambient temperature Relative humidity Vibration Shock resistance Housing material Size Weight FS-V21*1 FS-V21G FS-V21R (P) FS-V21X*1 Red LED Greed LED 4-element red LED Infrared (950 nm) 250 µs (FINE)/500µs (TURBO)/1ms (SUPER TURBO)/ 4ms (ULTRA TURBO)/500 µs (HIGH RESOLUTION)/ 50 µs (HIGH SPEED) Max. ±1999 (variable) Timer OFF, OFF-delay timer, ON-delay timer, and one- shot timer (1 to 500 ms) NPN open collector with 100 mA max at 40 V with a max*2, Residual voltage of 1 V. DC12-24V ±10% with a maximum ripple (peak to peak) of 10% Incandescent lamp: 20,000 Rx max. Sunlight: 30,000 Rx max. -10 °C to 55°C (No freezing) 35% to 85% RH (No condensation) 10 to 55 Hz, 1.5-mm double amplitude, each in X, Y, and Z directions for two hours 500 m/s2 Three times each in X, Y, and Z directions Unit and cover are both polycarbonate made W 9 mm x L70 mm x H 30 mm Approximately 80 g (including 2-m cable) Mode S-APC mode OFF 580 mW 480 mW 430 mW 650 mW 530 mW 480 mW S-APC mode turned ON or when the HIGH SPEED mode is selected. 720 mW 600 mW 550 mW 720 mW 600 mW 550 mW Normal ECO half ECO all Normal ECO half ECO all Model Other than R model R model *1. The model is sold only in Japan. Consult your KEYENCE representa- tive if the model is required outside Japan. *2. The maximum current will be 20 mA in the case of expansion. 13. List of Digital Display Items Preset value/Current value display Output selection (Dark ON) Output selection (Light-ON) Access mode selection (EASY) Access mode selection (FULL) Excess gain display LED bar display Hold display Power mode selection (FINE) Power mode selection (TURBO) Power mode selection (SUPER TURBO) Power mode selection (ULTRA TURBO) Power mode selection (HIGH SPEED) Power mode selection (HIGH RESOLUTION) Timer function setting (Timer OFF) Timer function setting (OFF-delay timer) Timer function setting (ON-delay timer) Timer function setting (One-shot timer) S-APC mode setting (S-APC OFF) S-APC mode setting (S-APC ON) Edge detection mode (OFF) Edge detection mode (Rising edge) Edge detection mode (Falling edge) ECO mode setting (ECO mode OFF) ECO mode setting (ECO half) ECO mode setting (ECO all) Shift function setting (Shift OFF) Shift function setting (Shift ON) Key lock setting Key unlock Forecast maintenance warning (END APC) WARRANTIES (MUST ACCOMPANY THE PRODUCTS): KEYENCE, at its sole option, will refund, repair or replace at no charge any defective Products within 1year from the date of shipment. Unless stated otherwise herein, the Products should not be used internally in humans, for human transportation, as safety devices or fail-safe systems. EXCEPT FOR THE FOREGOING, ALL EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-IN- FRINGEMENT OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED. KEYENCE SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES, EVEN IF DAMAGES RESULT FROM THE USE OF THE PRODUCTS IN ACCORDANCE WITH ANY SUGGESTIONS OR INFORMATION PROVIDED BY KEYENCE. In some jurisdictions, some of the foregoing warranty disclaimers or damage limitations may not apply. KEYENCE CORPORATION 1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku, Osaka, 533-8555, Japan PHONE: +81-6-6379-2211 FAX: +81-6-6379-2131 AFFILIATED COMPANIES KEYENCE CORPORATION OF AMERICA PHONE: 201-930-0100 FAX: 201-930-0099 KEYENCE DEUTSCHLAND GmbH PHONE: 06102-36 89-0 FAX: 06102-36 89-100 KEYENCE (UK) LIMITED PHONE: 01908-696900 FAX: 01908-696777 KEYENCE FRANCE S.A. PHONE: 01 47 92 76 76 FAX: 01 47 92 76 77 KEYENCE SINGAPORE PTE LTD. PHONE: 6392-1011 FAX: 6392-5055 KEYENCE (MALAYSIA) SDN BHD PHONE: 03-252-2211 FAX: 03-252-2131 KEYENCE (THAILAND) CO., LTD. PHONE: 02-369-2777 FAX: 02-369-2775 KEYENCE TAIWAN CO., LTD. PHONE: 02-2627-3100 FAX: 02-2798-8925 KEYENCE (HONG KONG) CO., LTD. PHONE: 3104-1010 FAX: 3104-1080 KEYENCE INTERNATIONAL TRADING (SHANGHAI) CO., LTD. PHONE: 021-68757500 FAX: 021-68757550 KEYENCE KOREA CORPORATION PHONE: 02-563-1270 FAX: 02-563-1271 Printed in Japan |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |