50 / 110 page ![]() Symbol Parameter Test condition Min Typ Max Unit Notes IIN_adc_lsb IIN ADC LSB CLK_SSM_EN = 0 - 53.2 - μV Application information ADC input accuracy IIN_adc_gain_err IIN ADC gain error -3 - 3 % - IIN_adc_offset_err IIN ADC input referred offset error -1 - 1 mV - IIN_adc_tot_err IIN ADC total error - - - mV See note ADC input dynamic characteristics IIN_adc_in_sr IIN ADC sample rate - 10 - MHz Application information IIN_adc_latency IIN ADC conversion latency CLK_SSM_EN = 0 - 65 100 μs Application information Note: IIN_ADC conversion total error can be calculated as follows: IIN_adc_tot_err = IIN_adc_gain_err * (POWERIN_P - POWERIN_N) + IIN_adc_offset_err Example: • | POWERIN_P-POWERIN_N | = 10 mV • Total ADC conversion error = ±1 mV ±(3% * 10 mV) = ±1 mV ±0.3 mV • The value read by PMBus™ has a range between 10 mV - (1 mV + 0.3 mV) and 10 mV + (1 mV + 0.3 mV) 3.11.2.1 Input current monitor (IIN monitor) Input current level is monitored by means of dedicated OC diagnosis based on IIN conversion. A hysteresis on thresholds and filtering time is implemented. If POWERIN_P- POWERIN_N ≥ IIN_off_th occurs for an interval longer than T_iin_mon_detect_dly, the fault is asserted and the IIN_OC flag is set. Fault pins are asserted LOW according to FHC configuration and FOR table. If POWERIN_P- POWERIN_N ≤ IIN_on_th occurs for an interval longer than T_iin_mon_detect_dly, the IIN_ OC fault is released. IIN_OC clearing depends on FHC configuration. The reference thresholds for the IIN monitor unit IIN_off_th and IIN_on_th can be separately configured through a dedicated PMBus™ register as follows: IINOFFTH=IINMONtℎlsb×IINOFFTH9:0 (6) IINONTH=IINMONtℎlsb×IINONTH9:0 (7) Where: IIN_MON_th_lsb is the minimum voltage step [53.2 µV]. IIN_OFF_TH/IIN_ON_TH [9:0] are the dedicated PMBus configuration bits [53.2 µV ~ 54.4 mV]. The default value is IIN_OFF_TH =0x11A (15 mV) and IIN_ON_TH = 0x0E1 (12 mV). In case IIN_OFF_TH = 0x000 the input current monitor function is disabled, and no OC detection is performed. The absolute value of the maximum input voltage slew rate detectable by IIN monitor is given by IIN_adc_lsb/ IIN_adc_latency. STPM098C Functional description DS14440 - Rev 1 page 50/110 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |