| Electronic Components Datasheet Search |
|
PD30ETDR10BPA2IO Datasheet(PDF) 6 Page - Carlo Gavazzi Holding AG |
|
|
|||||||||||||||||||||||||||||
PD30ETDR10BPA2IO Datasheet(HTML) 6 Page - Carlo Gavazzi Holding AG |
|
6 / 19 page ![]() 6 Carlo Gavazzi Industri A/S PD30ETDx10BPxxIO - IO-Link PD30ETDx10BPxxIO ENG 28/04/2021 Sensor switching channel SSC1 and SSC2 SSC1 • Enabled • Disabled Factory settings: Enabled SSC2 • Enabled • Disabled Factory settings: Enabled Set Point 1 (SP1) • 0 ... 13 500 Factory settings: 100 (Approx. 1000 mm @ Rererence target 90% reflection) Set Point 2 (SP2) • 0 ... 13 500 Factory settings: 13 500 (Approx. 100 mm @ Rererence target 90% reflection) Switching logic • High active • Low active Factory settings: High active Switching mode SSC1 • Deactivated • Single point mode • Two point mode • Windows mode Factory settings: Single point mode SSC2 • Deactivated • Single point mode • Two point mode • Windows mode Factory settings: Single point mode Rated operating distance (S n) 1000 mm Reference target, white paper with 90 % reflectivity, Size 200x200 mm Maximum detection distance < 1000 mm Rererence target 90% reflection Sensitivity control ( selectable be- tween) • IO-Link Adjustment (SSC1) • Trimmer Input (SSC1) • Teach by wire (SSC1) Factory settings: Trimmer Input Sensitivity adjustment 70 ... 13 500 Single-turn potentiometer Blind zone ≤1.0 mm @ Sn max Rererence target 90% reflection Light source / Light type 617 nm / Red modulated PD30ETDR10BPxxIO 850 nm / Infrared modulated PD30ETDI10BPxxIO Detection angle ± 1.4° @ half sensing distance @ 500 mm Light spot size Ø 46 mm @ 500 mm Emitter beam angle ± 2.6° @ 500 mm Adjustable distance • 0 ... 13 500 Factory settings: SP1 100 (1000 mm) and SP2 13 500 (100 mm) Rererence target 90% reflection Hysteresis (H) Manual Automatic Adjustable by IO-Link • 1% ... 100% Typical 5% ... 10% / Max. 15% Detection filter This function can increase the immunity towards unstable targets and electromagnetic disturbances: Value can be set from 1 to 255. Factory settings: 1 (1 is max. operating frequency and 255 is min. operating frequency) Mutual Inteference Protection • MIP Off • One channel • 2 channels - CH A • 2 channels - CH B • 3 channels - CH A • 3 channels - CH B • 3 channels - CH C Factory settings: MIP Off |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |