| Electronic Components Datasheet Search |
|
MCP2021 Datasheet(PDF) 9 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
MCP2021 Datasheet(HTML) 9 Page - Microchip Technology |
|
9 / 46 page ![]() © 2009 Microchip Technology Inc. DS22018E-page 9 MCP2021/2 1.5.8 FAULT/TXE Fault Detect output and Transmitter Enable input bidirectional pin. This pin is an open-drain output. Its state is defined as shown in Table 1-2. The transmitter driver is disabled whenever this pin is low (‘0’), either from an internal fault condition or by external drive. This allows the transmitter to be placed in an off state and still allow the voltage regulator to operate. Refer to Table 1-1. The FAULT/TXE also signals a mismatch between the TXD input and the LBUS level. This can be used to detect a bus contention. Since the bus exhibits a propagation delay, the sampling of the internal compare is debounced to eliminate false faults. This pin has an internal pull-up resistor of approximately 750 k Ω. The FAULT/TXE pin sampled at a rate faster than every 10 µs. TABLE 1-2: FAULT/TXE TRUTH TABLE 1.5.9 RESET RESET is an open-drain output pin. This pin tracks an internal signal that tracks the internal system voltage has reached a valid, stable level. As long as the internal voltage is valid, this pin will remain high (‘1’). When the system voltage drops below the minimum required, the voltage regulator will shut down and immediately convert the RESET output to (‘0’). When connected to a micro-controller input, this can provide a warning that the voltage regulator is shutting down (see Example 1- 2). Alternately, it can act as an external brown-out by connecting the RESET output to MCLR (see Example 1-3). In addition to monitoring the internal voltage, RESET is asserted immediately upon entering the Powerdown mode. Note 1: The FAULT/TXE pin is true (0) whenever the internal circuits have detected a short or thermal excursion and have disabled the LBUS output driver. 2: FAULT/TXE is true (0) when VREG not OK and has disabled the LBUS output driver. TXD In RXD Out LINBUS I/O Thermal Override FAULT/TXE Definition External Input Driven Output LH VBB OFF H L FAULT, TXD driven low, LINBUS shorted to VBB (Note 1) HH VBB OFF H H OK LL GND OFF H H OK HL GND OFF H H OK, data is being received from the LINBUS xx VBB ON H L FAULT, Tranceiver in thermal shutdown xx VBB xL x NO FAULT, the CPU is commanding the tranceiver to turn off the transmitter driver Legend: x = don’t care Note 1: The FAULT/TXE is valid after approximately 25 µs after TXD falling edge. This is to eliminate false fault reporting during bus propagation delays. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |