32 / 130 page ![]() 32 Am79C972 If the host is not yet ready when the Am79C972 control- ler asserts TRDY, the device will wait for the host to as- sert IRDY. When the host asserts IRDY and FRAME is still asserted, the Am79C972 controller will finish the first data phase by deasserting TRDY one clock later. At the same time, it will assert STOP to signal a discon- nect to the host. STOP will stay asserted until the host removes FRAME. See Figure 8. Figure 8. Disconnect Of Slave Burst Transfer - Host Inserts Wait States Parity Error Response When the Am79C972 controller is not the current bus master, it samples the AD[31:0], C/BE[3:0], and the PAR lines during the address phase of any PCI com- mand for a parity error. When it detects an address par- ity error, the controller sets PERR (PCI Status register, bit 15) to 1. When reporting of that error is enabled by setting SERREN (PCI Command register, bit 8) and PERREN (PCI Command register, bit 6) to 1, the Am79C972 controller also drives the SERR signal low for one clock cycle and sets SERR (PCI Status register, bit 14) to 1. The assertion of SERR follows the address phase by two clock cycles. The Am79C972 controller will not assert DEVSEL for a PCI transaction that has an address parity error when PERREN and SERREN are set to 1. See Figure 9. Figure 9. Address Parity Error Response During the data phase of an I/O write, memory-mapped I/O write, or configuration write command that selects the Am79C972 controller as target, the device samples the AD[31:0] and C/BE[3:0] lines for parity on the clock edge, and data is transferred as indicated by the asser- tion of IRDY and TRDY. PAR is sampled in the following clock cycle. If a parity error is detected and reporting of that error is enabled by setting PERREN (PCI Com- mand register, bit 6) to 1, PERR is asserted one clock later. The parity error will always set PERR (PCI Status register, bit 15) to 1 even when PERREN is cleared to 0. The Am79C972 controller will finish a transaction that has a data parity error in the normal way by assert- ing TRDY. The corrupted data will be written to the ad- dressed location. Figure 10 shows a transaction that suffered a parity error at the time data was transferred (clock 7, IRDY and TRDY are both asserted). PERR is driven high at the beginning of the data phase and then drops low due to the parity error on clock 9, two clock cycles after the data was transferred. After PERR is driven low, the Am79C972 controller drives PERR high for one clock cycle, since PERR is a sustained tri-state signal. FRAME CLK AD IRDY TRDY C/BE DEVSEL STOP 1 23456 PAR BE PAR PAR BE DATA 1st DATA 21485C-11 FRAME CLK AD SERR C/BE DEVSEL 1 2345 PAR PAR ADDR 1st DATA BE CMD PAR 21485C-12 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |