Back Button AN1709 Datasheet HTML 4Page - STMicroelectronics AN1709 Datasheet HTML 5Page - STMicroelectronics AN1709 Datasheet HTML 6Page - STMicroelectronics AN1709 Datasheet HTML 7Page - STMicroelectronics AN1709 Datasheet HTML 8Page - STMicroelectronics AN1709 Datasheet HTML 9Page - STMicroelectronics AN1709 Datasheet HTML 10Page - STMicroelectronics AN1709 Datasheet HTML 11Page - STMicroelectronics AN1709 Datasheet HTML 12Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 38 page
background image
8/38
EMC DESIGN GUIDE FOR ST MICROCONTROLLERS
Figure 5. Coupling Network
Measurements are performed on a ground plane. The generator is connected to ground plane
by a short wire. The supply wires are 10 cm from the ground plane. The DUT is on the insu-
lator 10 cm from the ground plane. The FTB voltage level is increased until the device failure.
Severity Levels and Class help application designers to determine which ST microcontrollers
are suitable for their target application, based on the susceptibility level (Severity level) and
type of behavior (Class) indicated in the datasheet.
2.1.1.3 ST Severity Level & Behavior Class
The 1000-4-2 and 1000-4-4 standards do not refer specifically to semiconductor components
such as microcontrollers. Usually electromagnetic stress is applied on other parts of the
system such as connectors, mains, supplies... The energy level of the F_ESD and FTB test
decreases before reaching the microcontroller, governed by the laws of physics. A large
amount of statistical data collected by ST on the behaviour of MCUs in various application en-
vironments has been used to develop a correlation chart between ST F_ESD or FTB test
voltage and 1000-4-2/1000-4-4 severity levels (See Table 3).
Table 3. ST ESD Severity levels
In addition to this severity level, MCU behaviour under ESD stress can be grouped into dif-
ferent Behaviour Classes (See Table 4) according to EN 50082-2 norm:
Severity Level
ESD (1000-4-2)
Equipment standard
(kV)
FTB (1000-4-4)
Equipment standard
(kV)
ST Testing Voltage
ST internal EMC test
(kV)
12
0.5
0-0.5
24
1
0.5-1
36
2
1-1.5
48
4
>1.5
TO THE DEVICE
POWER
SUPPLY
UNDER TEST
Cc
+VDD
GND
NSG 2025
GND
Cc
+VDD
L



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com