21 / 56 page ![]() Page 21 of 56 TM121 Rev: P1.3 Date: October 24, 2011 © Copyright the Connor-Winfield Corp. All Rights Reserved Specifications subject to change without notice STC5455 Synchronous Clock for SETS Functional Specification Data sheet Preliminary value. The alarm assert threshold value must be greater than the alarm de-assert threshold value and less than or equal to the bucket size value. Attempted writes of invalid values will be ignored. Therefore, user must carefully plan an appropriate sequence of writes when re-configure the activity monitor. See register Bucket Size, Assert Threshold and De Assert Threshold for details. Alarms appear in the Refs Activity register. A “1” indicates activity, and a “0” indicates an alarm, no activity. Note that if a reference is detected as a differ- ent frequency, the leaky bucket accumulator is set to the bucket size value and the reference will become inactive immediately. Input Qualification A selected reference is “qualified” if it passes the activity evaluation and its frequency offset is within the programmed qualification range for over a pre- programmed soaking time. A reference qualification range may be programmed up to 102.3 ppm by writing to register Qualification Range, and a disqualification range set up to 102.3 ppm, by writing to register Disqualification Range. The qualification range must be set less than the dis- qualification range. Additionally, qualification soaking time may be programmed from 0 to 63 seconds by writing to register Qualification Soaking Time. The pull-in range is the same as the disqualification range. Figure 3: Reference Qualification Scheme Activity Not Good Activity Good Qualified Activity Alarm Asserted Activity Alarm Asserted Activity Alarm De-Asserted Out of Disqualification Range Within Offset Qualification Range for more than Qualification soaking Time Continuously The frequency offset of each reference is relative to the internal freerun clock may be read by selecting the reference in the Ref Info Selector register and then reading the offset value from register Ref Info. Figure 3 shows the reference qualification scheme. A reference is qualified if it has no activity alarm and is continuous within the qualification range for more than the qualification soaking time. An activity alarm or frequency offset beyond the disqualification range will disqualify the reference. It may then be re-quali- fied if the activity alarm is off and the reference is within the qualification range for more than the qualifi- cation time. The reference qualification status of each reference may be read from register Ref Qual. Automatic Reference Election Mechanism The STC5455 has an auto reference elector always elect the best candidate from the reference inputs according to the revertivity status, each reference’s priority and qualification. This mechanism operates independent of reference selection mode. In other word, regardless what the current reference selection mode is, the auto reference elector always work in this mechanism. The detail description of the refer- ence selection mode is in following sections. The reference priority is indicated in the reference pri- ority table which is shown in register Ref Priority Table individually for each timing generator. Each ref- erence has one entry in the table, which may be set to value from 0 to 15. ‘0’ revokes the reference from the election, while 1 to 15 set the priority, where ‘1’ has the highest, and ‘15’ has the lowest priority. The high- est priority pre-qualified reference then is a candidate selected by the automatic reference elector. If multi- ple references share the same priority, the one that has been qualified for the longest time will be recom- mended to be the candidate. If the current highest pri- ority reference input fails, the next-highest priority reference is selected as the candidate. In order to avoid disturbance of the clock output, the candidate reference selected by automatic reference elector should be handled in two different mode. Revertive mode and non-revertive mode. The mode is determined by either enabling or disabling the “revertive” bit of the Control Mode to “1” for revertive or to “0” for non-revertive operation. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |