| Electronic Components Datasheet Search |
|
MCP452P Datasheet(PDF) 16 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
MCP452P Datasheet(HTML) 16 Page - Microchip Technology |
|
16 / 50 page ![]() MCRF450/451/452/455 DS40232H-page 16 2003 Microchip Technology Inc. 6.0 READ/WRITE ANTI-COLLISION LOGIC This section includes the anti-collision algorithm of the device and consists of the Anti-collision/command controller, the time slot generator and the time slot counter. 6.1 Description of Algorithm The read/write anti-collision algorithm is based on time division multiplexing of tag responses. Each device is allowed to communicate with the Interrogator in its time slot only. When not in its assigned time slot, the device remains in a nonmodulating condition. This enables the Interrogator to communicate with other devices in the same Interrogator field with fewer chances of data collision. Figure 6-1 shows the anti-collision algorithm flowchart, which consists of four control loops. They are: Detection, Processing, Sleeping and Reactivation loops. All devices in the Interrogator’s RF field are controlled by five different commands and internal control flags. The Interrogator commands are: 1. Fast Read Request (FRR): If the TF bit (bit 30 or Block 0) is cleared, the device responds only to the FRR command. The FRR command consists of five specially timed gap pulses (refer to Figures 6-3 to 6-7). The position of the five gap pulses in the given time span (1.575 ms) determines the parameters of the command. The command has three parameters: TCMAX, TSMAX and Data transmission speed. The details of these parameters will be discussed in the following sections. If the device receives the FRR command, it sends the FR response and then listens for 1 ms (T LW) for a matching code from the Interrogator. 2. Fast Read Bypass (FRB): This command is used in the Reactivation loop and is only appli- cable to a device with the FR bit (bit 31 in Block 0) cleared. The device responds with 64 bits of data, which includes Block 1 data (32-bit Tag ID), and then listens for 1 ms (T LW) for a match- ing code from the Interrogator. The command structure is the same as the FRR command: five specially timed gap pulses (1.575 ms). The command parameter (Figure 6-8) determines the data rate (normal speed or fast speed) of subsequent Interrogator commands. 3. Matching Code 1 (MC1): This command consists of time calibration pulses (TCP) followed by 1-of-16 PPM signals. It is used when the device does not need any further process- ing. This MC1 command causes a device, which is in the detection loop, to enter the sleeping loop. 4. Matching Code 2 (MC2): The command structure is the same as MC1: TCP followed by 1-of-16 PPM signals. The command is used when the device needs further processing (read/ write). The device enters the processing loop if it receives this command in the detection loop. The MC1 and MC2 matching code command consists of 12 bits or 3 symbols. The first 8 bits, or the first two symbols, are selected from the 32-bit Tag ID. The next 4 bits, or the 3rd symbol, determine the matching code type (3 bits) and a parity bit (see Section 6.2.3.6 “Calculation Of Matching Code”). The command lasts for about 11.2 ms, including the TCP. 5. End Process (EP): This command consists of the time reference pulses followed by 1-of-16 PPM signals. The EP command causes a device to exit the processing loop and enter the sleeping loop. 6.1.1 DETECTION LOOP If the FR bit (bit 31 of Block 0) is set, the device can enter this loop in two ways, depending on the condition of the TF bit (bit 30 of Block 0). They are: 1. When the TF bit is cleared, the device enters this loop and waits for a FRR command. This is called the “Interrogator-Talks-First” (ITF) mode. 2. When the TF bit is set, the device enters this loop by transmitting the FR response without waiting for an FRR command. This is called the “Tag-Talks-First” (TTF) mode. For case 1 above, the parameters of the FRR are: • Maximum number of time slots (TSMAX = 1, 16, or 64), • Maximum transmission counter (TCMAX = 1, 2, or 4), • Data transmission speed (Normal or Fast mode). The purpose of the TSMAX and TCMAX parameters is to acknowledge the device in the detection loop as fast as possible. TSMAX represents the maximum number of time slots between the end of the FRR command and the beginning of the FR response. One time slot (T SLOT) represents 2.5 ms. For example, TSMAX = 64 represents a maximum time delay of 160 ms before sending the FR response. See Section 6.3 “Time Slot Generator” for the calculation of actual time delay. TCMAX represents the maximum number of FR responses a device can send after an FRR command. For example, TCMAX = 4 means the device can send its FR response four times (after the FRR command) for acknowledgment (matching code). |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |