| Electronic Components Datasheet Search |
|
MCP452P Datasheet(PDF) 17 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
MCP452P Datasheet(HTML) 17 Page - Microchip Technology |
|
17 / 50 page ![]() 2003 Microchip Technology Inc. DS40232H-page 17 MCRF450/451/452/455 The TSMAX and TCMAX values are determined by the Interrogator’s decision on how many tags are in the field. The Interrogator may assign TSMAX = 1 and TCMAX = 1, assuming there is only one tag in the field. The efficiency of the detection will increase in multiple tag environments by assigning a higher number to both the TSMAX and TCMAX. If the device receives the FRR, it clears the Position 1 flag, waits for its time slot, replies with the FR response and then listens for 1 ms. The FR response consists of a maximum of 160 Manchester data bits (default: 96 bits), which includes the 32-bit Tag ID and the FRF data (Blocks 3-5) (see Table 6-3 and Example 9-1). To acknowledge the FR response, the Interrogator can start to send a matching code (MC) during the device’s 1 ms listening window (T LW). The MC is encoded with 1-of-16 PPM signal (see Figure 6-9). The MC1 is given to the device if the device does not need any further processing. If the device receives the MC1, it enters the sleeping loop and stays in the loop in a nonmodulating condition. The MC2 command is given to the device if further processing (read/write) is required. If the device receives the MC2 command, it enters the processing loop. If the device misses the MC within the listening window, it sends the FR response again after its time slot when two conditions are met: (1) Position 1 flag is cleared and, (2) TCMAX has not elapsed. The device checks the condition (elapsed or not elapsed) of TCMAX using an internal transmission counter (TC). The TC consists of 3 bits. If the Position 1 flag is cleared, the device increments the TC by 1 each time it does not receive a MC during its listening window. See Figure 6-1 for a flow chart showing the conditional incrementing of the transmission counter. Table 6-1 shows an example of detecting the elapsed TCMAX using a rolling modulo-8 transmission counter. For the TTF case, the device repeats its FR response (as long as it is energized) according to the TCMAX and TSMAX parameters, as specified in Table 7-5. Even though the device is operating in the TTF mode, it will respond to its correct MC during its listening window. If TCMAX = 1, 2 or 4, it will also respond to FRR commands, just as in the ITF case (see Section 6.1.1.1 “Matching Code Queuing”). 6.1.1.1 Matching Code Queuing Once the device receives the FRR command, it sends the FR response and waits for a matching code (MC) during its listening window. If the device does not receive its correct MC code before its TCMAX has elapsed (see Table 6-1), it goes back to the beginning of the detection loop (position 1 in the loop) and waits for either a new FRR command or for the MC1 or MC2 matching code. This is called “matching code queuing”. In this queuing, the device stays in the detection loop waiting for an Interrogator command (FRR or MC). This queuing takes place within the detection loop and is controlled by the conditions of "Set Position 1 Flag" and TCMAX. This queuing allows the Interrogator to communicate with a device outside its listening window. The result is enhanced and accelerated processing of individual devices in a multiple tag environment. TABLE 6-1: CONDITIONS FOR TCMAX = ELAPSED FOR ITF MODE 6.1.2 PROCESSING LOOP The reading and writing processes take place in this loop. Devices in this loop are waiting for commands for processing. In order to read from, or write to, the device, its “Processing Flag” (PF) must be set. Any device entering this loop with its PF cleared is called a “follow-along” tag. This follow-along tag in the loop is not processed for reading or writing. If the device with the PF flag set receives the EP command, it exits this loop and enters the sleeping loop. However, the same EP command sends the follow-along tag back to the detection loop. If the device receives the FRR or FRB command in this loop, it sees the command as invalid, resets itself and goes back to the initial power-up state. 6.1.3 SLEEPING LOOP The sleeping loop is used to keep all processed devices in a “silent” condition. The devices stay in this loop in a nonmodulating condition as long as they remain in the field. Rolling Modulo -8 TC TCMAX = 1 TCMAX = 2 TCMAX = 4 001 elapsed — — 010 elapsed elapsed — 011 elapsed — — 100 elapsed elapsed elapsed 101 elapsed — — 110 elapsed elapsed — 111 elapsed — elapsed 000 elapsed elapsed — |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |