| Electronic Components Datasheet Search |
|
MPXM2102AS Datasheet(PDF) 562 Page - Motorola, Inc |
|
|
|||||||||||||||||||||||||||||
MPXM2102AS Datasheet(HTML) 562 Page - Motorola, Inc |
|
562 / 670 page ![]() AN4007 3–416 Motorola Sensor Device Data www.motorola.com/semiconductors TRANSFER FUNCTION The behavior of an IPS is defined by a linear transfer function. This transfer function applies to all Motorola’s Integrated Pressure Sensors whatever the pressure range and type of sensing element (absolute or differential). Vout + VS (P K1 ) K2) " (PE TM V S K1) • Vout : Sensor output voltage • P: Applied pressure in kPa • Vs: Sensor supply voltage in V • K1: Sensitivity constant in V/V/kPa • K2: Offset Constant inV/V • PE: Pressure error in kPa • TM: Temperature multiplier The constants, K1, K2, PE & TM are specific to each device, temperature and pressure encountered in the application. The variables P and Vs are dependent on the user application but must remain within the operating specification of the device. THE MPXV6115VC6U INTEGRATED PRESSURE SENSOR The Motorola MPXV6115VC6U gauge vacuum sensor, designed to measure pressure below the atmospheric pressure, is suitable for automotive application such as vacuum pump or brake booster monitoring. The MXPV4115V is also ideal for non–automotive applications where vacuum control is required. The MPXV6115VC6U has the following basic characteristics (Note: Detailed characteristics of Motorola’s pressure sensors can be found on http://www.motorola.com/semiconductors). MPXV6115VC6U CHARACTERISTICS Vout + VS (P 0.007652 ) 0.92) " (PE TM V S 0.007652) Figure 6. MPXV6115VC6U Transfer Function TRANSFER FUNCTION: Vout = 2.30 V @ P = –60 kPa Vout = VS ([0.007652 *P] + 0.92) –120 –100 –80 –60 –20 0 0 1 2 3 4 5 VACUUM in kPa (below atmospheric pressure) 20 –40 VACUUM • P is the applied vacuum to the sensor pressure port. Pressures below atmospheric pressure have a negative sign. For example, 50 kPa below atmospheric is P = –50 in the transfer function. For pressure higher than the atmospheric pressure, the device will electrically satu- rate. The sensor is designed to measure vacuum from 0 kPa (Atmospheric pressure applied to the sensor pres- sure port) down to – 115kPa. Since the MPXV6115VC6U is using the atmospheric pressure as reference, –115 kPa can only be reached if the atmospheric pressure is higher or equal than 115 kPa. The device will electrically saturate for vacuum below –115 kPa. • PE = 1.725 kPa (1.5% of full scale span) over the entire pressure range • TM = 1 between 0 and +85_C, 3 at –40_C and +125_C. TM is a linear response from –40 _ to 0_C and from 85_ to 125 _C. The real intent for the pressure–sensor user is to know the measured pressure. In this case it is preferable to express the transfer function as: P + (V out VS * 0.92) 0.007652 " (PE TM) As an example, if Vout = 2.30 V for a 5 Vdc power supply and at 25 _C ambient temperature, the measured vacuum is P = –60.1 kPa " 1.725 kPa. Freescale Semiconductor, Inc. For More Information On This Product, Go to: www.freescale.com |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |