13 / 23 page ![]() Data Sheet ADIS16446 Rev. 0 | Page 13 of 23 INTERNAL TEMPERATURE The internal temperature measurement data loads into the TEMP_OUT register (see Table 17). Table 18 illustrates the temperature data format. Note that this temperature represents an internal temperature reading and does not precisely represent external conditions. The intended use of TEMP_OUT is to monitor relative changes in temperature. Table 17. TEMP_OUT (Base Address = 0x18), Read Only Bits Description [15:12] Not used [11:0] Twos complement, 0.07386°C/LSB, 31°C = 0x000 Table 18. Temperature, Twos Complement Format Temperature (°C) Decimal Hex Binary +105 +1002 3EA 0011 1110 1010 +85 +731 2DB 0010 1101 1011 +31.14772 +2 2 0000 0000 0010 +31.07386 +1 0 0000 0000 0001 +31 0 0 0000 0000 0000 +30.92614 −1 FFF 1111 1111 1111 +30.85228 −2 FFE 1111 1111 1110 −40 −962 C3E 1100 0011 1110 |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|