| Electronic Components Datasheet Search |
|
BPD1002 Datasheet(PDF) 12 Page - Bel Fuse Inc. |
|
|
|||||||||||||||||||||||||||||
BPD1002 Datasheet(HTML) 12 Page - Bel Fuse Inc. |
|
12 / 15 page ![]() BCD.00617 Rev AB,16-Nov-2015 Page 12 of 15 MELCHER The Power Partners. Accessories Data Sheet Backplanes BPD, BPF for T Series Mechanical fixing shall be made via 10 screws M2.5 × 10 and 10 nuts M2.5. When mounting a back plane to a rack, fit two T units into the H 15 female connectors on the back plane prior to fixing the back plane to the rack. This ensures correct positioning of the female connectors on the back plane with respect to the given position of the male connectors of the T units in the rack. With the back plane improperly positioned, the connectors of the T units and the female connectors on the back plane may be damaged. In order to maintain correct positioning, use all the available mounting holes. Connection to the supply system shall be made via the 6-pole screw terminal connector X1 according to Connector Pin Allo- cation and Mechanical Data. The connector X1 of the back planes (class I equipment) is provided with two protective earth terminals ( ), which are reliably connected with the protective earth pins of the connec- tors for the T units. For safety reasons it is essential to connect at minimum one of these terminals with the protective earth of the supply system. Since the earth leakage current exceeds 3.5 mA, the system must be permanently connected or it must be pluggable equipment type B according to IEC/EN 60950. The earth connection must be performed before connecting the supply. To maintain good electrical connection, the AC input, earth and signal to the terminal strip wiring should be secured, using tie wraps, to prevent stress upon the wires and the connectors. Refer to Mains Input Section to ensure that phase and neutral configuration matches with the back plane and T series AC- DC converter types. Wrong connection at the input may damage the T series AC-DC converters as well as the back plane. Standard back planes are designed for a 3-phase system in Y connection with a phase to neutral voltage of 230 VAC or 120 VAC where connection to neutral is mandatory. Integration into a 3-phase system in ∆ configuration (120/208 VAC and without connection to neutral) is only possible with LT type converters together with the special back plane BPF1037. For safety reasons, a mains switch for line interruption is required. The back plane does not provide any input fuses. The input fuses of the T series AC-DC converters in the connection from the L terminal are designed to protect the units in case of overcurrent and may not be able to satisfy all customer requirements. An external input fuse suitable for the applica- tion and in compliance with the local requirements in the wiring to each phase and to the neutral terminal may therefore be necessary to ensure compliance with local requirements. A second fuse in the wiring to each input terminal is needed if: • Standard back planes are used in phase to phase configuration. • Local requirements demand an individual fuse in each source line. • Neutral to earth impedance is high or undefined. • Phase and neutral of the mains are not defined or cannot be assigned to the corresponding terminals (L to phase and N to neutral). Important: Do not open the modules, or guarantee will be invalidated. Additional Information for Installation of Battery Charger Systems: Reverse polarity connection of the battery may damage the battery, the back plane(s) and the battery chargers. Prior to putting a system into operation, check whether the position of the cell voltage selector switch of each T Series converter corresponds to the required battery cell voltage. For battery maintenance please contact the battery manu- facturer. Exchanging a battery should always include the whole battery bank. New batteries should be of the same type, with the same cell voltage and temperature coefficient. For expansion of battery systems contact the battery manufac- turer. For battery location and connection please refer to VDE 0510, part 2. In battery charger systems, safety standards demand that a battery can be completely disconnected from the power sys- tem including the battery system ground. Depending upon the project specific requirements, disconnecting may either occur by a manually operated switch with fuses, or automatically by means of a circuit breaker. Caution: Care should be taken during system set-up or after maintenance when connecting a battery to the power bus of a back plane (BPF types) fitted with fuses. The T Series converter system with the back planes should be switched to the mains prior to connecting the battery to the power bus, since the reverse current from the battery into the uncharged output capacitors of the T units and the back plane may damage the fuses. Make sure that there is sufficient air flow available for convec- tion cooling. This should be verified by measuring the case temperature of each T Series converter when the complete back plane is installed and operated in the end-use application. The maximum specified case temperature TCmax of the T Series converters must not be exceeded. Ensure that a unit failure (e.g. by an internal short-circuit) does not result in a hazardous condition. See also Safety of operator accessible output circuit. Standards and Approvals All back planes correspond to class I equipment. They have been designed in accordance with UL 1950 and IEC/EN 60950 standards. Safety approvals are not provided. BPD1002 was approved according to UL60950-1 2nd Ed. A CB scheme for BPD1002 is available. The units have been evaluated for: • Building in • Basic insulation between input and earth, based upon 250 V |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |