Electronic Components Datasheet Search
  British  ▼
ALLDATASHEET.CO.UK

X  

X80121 Datasheet(PDF) 9 Page - Renesas Technology Corp

Part # X80121
Description  Voltage Supervisor/Sequencer Dual Programmable Time Delay with Local/Remote Voltage Monitors
PDF  17 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  RENESAS [Renesas Technology Corp]
Direct Link  http://www.renesas.com
Logo RENESAS - Renesas Technology Corp

X80121 Datasheet(HTML) 9 Page - Renesas Technology Corp

Back Button X80121 Datasheet HTML 5Page - Renesas Technology Corp X80121 Datasheet HTML 6Page - Renesas Technology Corp X80121 Datasheet HTML 7Page - Renesas Technology Corp X80121 Datasheet HTML 8Page - Renesas Technology Corp X80121 Datasheet HTML 9Page - Renesas Technology Corp X80121 Datasheet HTML 10Page - Renesas Technology Corp X80121 Datasheet HTML 11Page - Renesas Technology Corp X80121 Datasheet HTML 12Page - Renesas Technology Corp X80121 Datasheet HTML 13Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 9 / 17 page
background image
X80120, X80121
FN8151 Rev 0.00
Page 9 of 17
January 20, 2005
Manual Reset
The manual reset option allows a hardware reset of the power
sequencing pins. These can be used to recover the system in
the event of an abnormal operating condition. Activating the
MR pin for more than 5
s sets all of the ViGDO outputs and the
RESET output active (LOW). When MR is released (and if all
supplies are still at their proper operating voltage) then the
ViGDO and RESET pins will be released after their
programmed delay periods.
Dual Voltage Monitoring
X80120 monitors 2 voltage inputs. When the V1MON or
V4MON input is detected to be above the input threshold, the
respective output (V1GDO or V4GDO) goes inactive (LOW).
The ViGDO signal is de-asserted after a delay of 100ms. This
delay can be changed on each ViGDO output individually with
bits in register CR3. The delay can be 100ms, 500ms, 1s and
5s. Each ViGDO signal remains active until its associated
ViMON input rises above the threshold.
Fault Detection
The X80120 contains a Fault Detection Register (FDR) that
provides the user the status of the causes for a RESET pin
active (See Table 20).
At power-up, the FDR is defaulted to all “0”. The system needs
to initialize the register to 09h before the actual monitoring can
take place. In the event that any one of the monitored sources
fail, the corresponding bit in the register changes from a “1” to
a “0” to indicate the failure. When a RESET is detected by the
main controller, the controller should read the FDR and note
the cause of the fault. After reading the register, the controller
can reset the register bit back to all “1” in preparation for future
failure conditions.
Flexible Power Sequencing of Multiple Power
Supplies
The X80120 provides several circuits such as multiple voltage
monitors, programmable delays, and output drive signals that
can be used to set up flexible power monitoring or sequencing
schemes system power supplies. Below are two examples:
1. Power Up of Supplies In Parallel Using Programmable
Delays. (See Figure 7 and Figure 8).
The X80120 monitors several power supplies, powered by
the same source voltage, that all begin power up at the
same time. Each voltage source is fed into the ViMON
inputs to the X80120. The ViMON inputs monitor the
voltage to make sure it has reached the minimum desired
level. When each voltage monitor determines that its input
is good, a counter starts. After the programmed delay time,
the X80120 sets the ViGDO signals LOW. The ViGDO
signals can be wire ORed together and tied to an interrupt
on the microcontroller. Any individual voltage failure can be
viewed in the Fault Detection Register.
In the factory default condition, each ViGDO output is
instructed to go LOW 100ms after the input voltage reaches
its threshold. However, each ViGDO delay is individually
selectable as 100ms, 500ms, 1s and 5s. The delay times
are charged via the SMBus during calibration of the system.
2. Power Up of Supplies Via Relay Sequencing Using Voltage
Monitors (see Figure 9 and Figure 10).
Several power supplies and their respective power up start
times can be controlled using the X80120 such that each of
the power supplies will start in a relay sequencing fashion.
In the following example, the 1st supply is allowed to power
up when the input regulated supply reaches an acceptable
threshold. Subsequent supplies power up after the prior
supply has reached its operating voltage. This configuration
ensures that each subsequent power supply turns on after
the preceding supplies voltage output is valid. Again, the
X80120 offers programmable delays for each voltage
monitor and this delay is selectable via the SMBus during
calibration of the system.
TABLE 2. ViGDO OUTPUT TIME DELAY OPTIONS
TiD1
TiD0
tDELAYi
0
0
100ms (default)
0
1
500ms
1
0
1 secs
1
1
5 secs
where i is the specific voltage monitor (i = 1, 4).
V4GDO
V4MON
V1GDO
V1MON
X80120/21
RESET
µC
VCC1
FPGA
VCC1
ASIC
VCC1
RESET
VCC2
MR
1.2V
3.3V
5V
Power
Supplies
IRQ
On/Off
On/Off
FIGURE 7. EXAMPLE APPLICATION OF PARALLEL POWER
CONTROL



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com