21 / 67 page ![]() ADT7476 http://onsemi.com 21 Fan Limit Registers Register 0x54, TACH1 Minimum Low Byte = 0xFF default Register 0x55, TACH1 Minimum High Byte = 0xFF default Register 0x56, TACH2 Minimum Low Byte = 0xFF default Register 0x57, TACH2 Minimum High Byte = 0xFF default Register 0x58, TACH3 Minimum Low Byte = 0xFF default Register 0x59, TACH3 Minimum High Byte = 0xFF default Register 0x5A, TACH4 Minimum Low Byte = 0xFF default Register 0x5B, TACH4 Minimum High Byte = 0xFF default Out−of−Limit Comparisons Once all limits have been programmed, the ADT7476 can be enabled for monitoring. The ADT7476 measures all voltage and temperature measurements in round robin format and sets the appropriate status bit for out−of−limit conditions. TACH measurements are not part of this round robin cycle. Comparisons are done differently depending on whether the measured value is being compared to a high or low limit. High Limit: > Comparison Performed Low Limit: ≤ Comparison Performed Voltage and temperature channels use a window comparator for error detecting and, therefore, have high and low limits. Fan speed measurements use only a low limit. This fan limit is needed only in manual fan control mode. Analog Monitoring Cycle Time The analog monitoring cycle begins when a 1 is written to the start bit (Bit 0) of Configuration Register 1 (0x40). The ADC measures each analog input in turn, and, as each measurement is completed, the result is automatically stored in the appropriate value register. This round robin monitoring cycle continues unless disabled by writing a 0 to Bit 0 of Configuration Register 1. As the ADC is normally left to free−run in this manner, the time taken to monitor all the analog inputs is normally not of interest, because the most recently measured value of any input can be read out at any time. For applications where the monitoring cycle time is important, it can easily be calculated. The total number of channels measured is: • Four dedicated supply voltage inputs • Supply voltage (VCC pin) • Local temperature • Two remote temperatures As mentioned previously, the ADC performs round robin conversions and takes 11 ms for each voltage measurement, 12 ms for a local temperature reading, and 39 ms for each remote temperature reading. The total monitoring cycle time for averaged voltage and temperature monitoring is, therefore, nominally: (5 11) ) 12 ) (2 39) + 145 ms (eq. 3) Fan TACH measurements are made in parallel and are not synchronized with the analog measurements in any way. Status Registers The results of limit comparisons are stored in Interrupt Status Register 1 and Interrupt Status Register 2. The status register bit for each channel reflects the status of the last measurement and limit comparison on that channel. If a measurement is within limits, the corresponding status register bit is cleared to 0. If the measurement is out−of−limits, the corresponding status register bit is set to 1. The state of the various measurement channels can be polled by reading the status registers over the serial bus. In Bit 7 (OOL) of Interrupt Status Register 1 (0x41), 1 means an out−of−limit event has been flagged in Interrupt Status Register 2. This means the user also needs to read Interrupt Status Register 2. Alternatively, Pin 10 or Pin 14 can be configured as an SMBALERT output. This hard interrupt automatically notifies the system supervisor of an out−of−limit condition. Reading the status registers clears the appropriate status bit as long as the error condition that caused the interrupt has cleared. Status register bits are sticky. Whenever a status bit is set, indicating an out−of−limitcondition, it remains set even if the event that caused it has gone away (until read). The only way to clear the status bit is to read the status register after the event has gone away. Interrupt mask registers (0x74 and 0x75) allow individual interrupt sources to be masked from causing an SMBALERT. However, if one of these masked interrupt sources goes out−of−limit, its associated status bit is set in the status registers. Interrupt Status Register 1 (0x41) Bit 7 (OOL) = 1, denotes a bit in Interrupt Status Register 2 is set and Interrupt Status Register 2 should be read. Bit 6 (R2T) = 1, Remote 2 temperature high or low limit has been exceeded. Bit 5 (LT) = 1, Local temperature high or low limit has been exceeded. Bit 4 (R1T) = 1, Remote 1 temperature high or low limit has been exceeded. Bit 3 (5.0 V) = 1, 5.0 V high or low limit has been exceeded. Bit 2 (VCC) = 1, VCC high or low limit has been exceeded. Bit 1 (VCCP) = 1, VCCP high or low limit has been exceeded. Bit 0 (2.5 V) = 1, 2.5 V high or low limit has been exceeded. If the 2.5 V input is configured as THERM, this bit represents the status of THERM. Interrupt Status Register 2 (0x42) Bit 7 (D2) = 1, indicates an open or short on D2+/D2– inputs. Bit 6 (D1) = 1, indicates an open or short on D1+/D1– inputs. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |