| Electronic Components Datasheet Search |
|
ADE7759 Datasheet(PDF) 32 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE7759 Datasheet(HTML) 32 Page - Analog Devices |
|
32 / 36 page ![]() REV. A ADE7759 –32– 0 000 000 0 000 01 10 0 15 14 13 12 11 10 98765 4 3210 ADDR: 06H DISHPF (DISABLE HPF1 IN CHANNEL 1) DISLPF2 (DISABLE LPF2 AFTER MULTIPLIER) DISCF (DISABLE FREQUENCY OUTPUT CF) DISSAG (DISABLE SAG OUTPUT) ASUSPEND (SUSPEND CH1 AND CH2 ADCs) STEMP (START TEMPERATURE SENSING) SWRST (SOFTWARE CHIP RESET) CYCMODE (LINE CYCLE ENERGY ACCUMULATION MODE) TEST1 (TEST MODE SELECTION SHOULD BE SET TO 0) WAVSEL (WAVEFORM SELECTION FOR SAMPLE MODE) 00 = LPF2 01 = CH1 + CH2 (40-BIT WAVEFORM SAMPLES) 10 = CH1 11 = CH2 DTRT (WAVEFORM SAMPLES OUTPUT DATA RATE) 00 = 27.9kSPS (CLKIN/128) 01 = 14.4kSPS (CLKIN/256) 10 = 7.2kSPS (CLKIN/512) 11 = 3.6kSPS (CLKIN/1024) SWAP (SWAP CH1 AND CH2 ADCs) DISCH2 (SHORT THE ANALOG INPUTS ON CHANNEL 2) DISCH1 (SHORT THE ANALOG INPUTS ON CHANNEL 1) NOTE: REGISTER CONTENTS SHOW POWER-ON DEFAULTS Figure 48. Mode Register Interrupt Status Register (04H)/Reset Interrupt Status Register (05H) The status register is used by the MCU to determine the source of an interrupt request ( IRQ). When an interrupt event occurs in the ADE7759, the corresponding flag in the interrupt status register is set logic high. If the enable bit for this flag is Logic 1 in the inter- rupt enable register, the IRQ logic output goes active low. When the MCU services the interrupt, it must first carry out a read from the interrupt status register to determine the source of the interrupt. Table VII. Interrupt Status Register, Reset Interrupt Status Register, and Interrupt Enable Register Bit Interrupt Location Flag Description 0 AEHF Indicates that an interrupt was caused by the 0 to 1 transition of the MSB of the active energy register. 1 SAG Indicates that an interrupt was caused by a SAG on the line voltage or no zero crossings were detected. 2 CYCEND Indicates the end of energy accumulation over an integer number of half line cycles as defined by the content of the LINECYC register—see Line Cycle Energy Accumulation Mode section. 3 WSMP Indicates that new data is present in the waveform register. 4ZXThis status bit reflects the status of the ZX logic output—see Zero Crossing Detection section. 5 TEMP Indicates that a temperature conversion result is available in the temperature register. 6 RESET Indicates the end of a reset (for both software or hardware reset). The corresponding enable bit has no function in the interrupt enable register, i.e., this status bit is set at the end of a reset, but it cannot be enabled to cause an interrupt. 7 AEOF Indicates that the active energy register has overflowed. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |