Back Button STEF12E Datasheet HTML 4Page - STMicroelectronics STEF12E Datasheet HTML 5Page - STMicroelectronics STEF12E Datasheet HTML 6Page - STMicroelectronics STEF12E Datasheet HTML 7Page - STMicroelectronics STEF12E Datasheet HTML 8Page - STMicroelectronics STEF12E Datasheet HTML 9Page - STMicroelectronics STEF12E Datasheet HTML 10Page - STMicroelectronics STEF12E Datasheet HTML 11Page - STMicroelectronics STEF12E Datasheet HTML 12Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 19 page
background image
Figure 5. Delay time and VOUT ramp-up time
0
2
4
6
8
10
12
Time
En/fault
VOUT
delay
time
ramp -up
time
AMG300320171104MT
6.8
En/fault pin
The En/fault pin has the dual function to control the output of the device and, at the same time, provide the
application with information about the device status.
When it is used as a standard enable pin, it should be connected to an external open-drain or open-collector
device. In this case, when it is pulled to low logic level, it turns the output of the E-Fuse off.
If this pin is left floating, since it has an internal pull-up circuitry, the output of the E-Fuse is kept on, in normal
operating conditions.
In case of thermal fault, the pin is pulled to an intermediate state (Figure 6. En/fault pin status). This signal can
be provided to a monitor circuit, informing it that a thermal shutdown has occurred, or it can be directly connected
to the Enable/fault pin of the other STEFxx devices on the same application in order to achieve a simultaneous
enable/disable feature.
When a thermal fault occurs, the device can be reset either by cycling the supply voltage or by pulling down the
Enable pin below the VIL threshold and then releasing it.
Figure 6. En/fault pin status
STEF12E
En/fault pin
DS12800 - Rev 2
page 8/19



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com