24 / 97 page ![]() ADBMS2950B Data Sheet Rev. 0 | Page 24 of 97 Table 31. Write Data PEC Format Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 DPEC0 0 0 0 0 0 0 PEC[9] PEC[8] DPEC1 PEC[7] PEC[6] PEC[5] PEC[4] PEC[3] PEC[2] PEC[1] PEC[0] Table 32. Read Command Counter and Data PEC Format Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 DPEC0 CCNT[5] CCNT[4] CCNT[3] CCNT[2] CCNT[1] CCNT[0] PEC[9] PEC[8] DPEC1 PEC[7] PEC[6] PEC[5] PEC[4] PEC[3] PEC[2] PEC[1] PEC[0] Command Counter A command counter, CCNT[5:0] as shown in Table 32, enhances system level software diagnostics and communication integrity. The command counter is initialized to 0 on power cycling, by the SRST or by the RSTCC command. The command counter increments if ADBMS2950B receives a command without data, which are the 4-byte commands like SNAP, UNSNAP, and ADI1, or if it receives a command with write data such as WRCFGA and CLRFLAG. For a command to be received, the command PEC and data PEC should match. When the command counter increments past the maximum value of 63, it rolls over to a value of 1, not 0. The 0 value is reserved for specific reset cases listed previously. All read commands return the register data followed by the command counter and data PEC. The host controller can keep track of the expected command counter while sending commands and compare it with the CCNT value received from the ADBMS2950B with every read command. It is the responsibility of the host controller to confirm that SPI frames are received in time as expected, to verify the data checksum, and to track the command counter. Polling Methods Single Device SPI Polling In configurations that communicate in SPI mode, there are two methods of polling. The first method is to hold CSB low after an ADC conversion command is sent. After entering a conversion command, the SDO line is driven low when the device is busy performing conversions. SDO is pulled high when the device completes conversions. However, the SDO also returns to high when CSB goes high even if the device has not completed the conversion (see Figure 23). A problem with this method is that the controller is not free to do other serial communication while waiting for ADC conversions to complete. The next method overcomes this limitation. The controller can send an ADC command, perform other tasks, and then send a Poll command to determine the status of the ADC conversions. After entering the Poll command, SDO goes low if the device is busy performing operations. SDO is pulled high at the end of operations. However, SDO also goes high when CSB goes high, even if the device has not completed the operation. Figure 23. SDO Polling After an ADC Conversion Command (Single Device Configuration) Figure 24. SDO Polling Using PLADC Command (Single Device Configuration) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |