60 / 89 page ![]() PSD4235G2 60/89 Figure 32. APD Unit Automatic Power-down (APD) Unit and Power- down Mode. The APD Unit, shown in Figure 32, puts the PSD into Power-down mode by monitor- ing the activity of Address Strobe (ALE/AS, PD0). If the APD Unit is enabled, as soon as activity on Address Strobe (ALE/AS, PD0) stops, a four bit counter starts counting. If Address Strobe (ALE/ AS, PD0) remains inactive for fifteen clock periods of CLKIN (PD1), Power-down (PDN) goes High, and the PSD enters Power-down mode, as dis- cussed next. Table 48. Effect of Power-down Mode on Ports Power-down Mode. By default, if you enable the APD Unit, Power-down mode is automatically en- abled. The device enters Power-down mode if Ad- dress Strobe (ALE/AS, PD0) remains inactive for fifteen periods of CLKIN (PD1). The following should be kept in mind when the PSD is in Power-down mode: s If Address Strobe (ALE/AS, PD0) starts pulsing again, the PSD returns to normal operation. The PSD also returns to normal operation if either PSD Chip Select Input (CSI, PD2) is Low or the Reset (RESET) input is High. s The MCU address/data bus is blocked from all memory and PLDs. s Various signals can be blocked (prior to Power- down mode) from entering the PLDs by setting the appropriate bits in the Power Management Mode Registers (PMMR). The blocked signals include MCU control signals and the common CLKIN (PD1). Note that blocking CLKIN (PD1) from the PLDs does not block CLKIN (PD1) from the APD Unit. s All PSD memories enter Stand-by mode and are drawing Stand-by current. However, the PLDs and I/O ports blocks do not go into Stand-by mode because you do not want to have to wait for the logic and I/O to “wake-up” before their outputs can change. See Table 48 for Power- down mode effects on PSD ports. s Typical Stand-by current is or the order of µA. This Stand-by current value assumes that there are no transitions on any PLD input. Table 49. PSD Timing and Stand-by Current during Power-down Mode Note: 1. Power-down does not affect the operation of the PLD. The PLD operation in this mode is based only on the Turbo bit. 2. Typical current consumption, see Table 60, assuming no PLD inputs are changing state and the PLD Turbo bit is 0. APD EN PMMR0 BIT 1=1 ALE RESET CSI CLKIN TRANSITION DETECTION EDGE DETECT APD COUNTER POWER DOWN (PDN) Select DISABLE BUS INTERFACE Secondary Flash Memory Select Primary Flash Memory Select SRAM Select PD CLR PD DISABLE Primary and Secondary FLASH Memory and SRAM PLD AI04939 Port Function Pin Level MCU I/O No Change PLD Out No Change Address Out Undefined Data Port Tri-State Peripheral I/O Tri-State Mode PLD Propagation Delay Memory Access Time Access Recovery Time to Normal Access Typical Stand-by Current Power-down Normal tPD (Note 1) No Access tLVDV ISB (Note 2) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |