| Electronic Components Datasheet Search |
|
AD9920ABBCZ Datasheet(PDF) 101 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9920ABBCZ Datasheet(HTML) 101 Page - Analog Devices |
|
101 / 112 page ![]() AD9920A Rev. B | Page 101 of 112 Table 59. Shutter and GPO Registers Address Data Bits Default Value Update Type Name Description 0x70 [2:0] 0 VD PRIMARY_ACTION Select action for primary and secondary counters. [5:3] 0 SECOND_ACTION 0 = idle (do nothing): autoreset on VD. 1 = activate counter (primary: automatic exposure/read). 2 = RapidShot: wrap/repeat counter. 3 = ShotTimer: delay start of count. 4 = ShotTimer with RapidShot. 5 = SLR exposure (manual). 6 = SLR read (manual). 7 = force to idle. [13:6] 0 MANUAL_TRIG 1: manual trigger for GP signals when Protocol 1 is selected. Bit 6: GP1 manual trigger. Bit 13: GP8 manual trigger. 0x71 [12:0] 0 VD PRIMARY_MAX Primary counter maximum value. [24:13] 0 SECOND_MAX Secondary counter maximum value. [27:25] 0 VDHD_MASK Mask VD/HD during counter operation. 0x72 [12:0] 0 VD PRIMARY_DELAY Number of fields to delay before the next primary count (exposure) starts. For ShotTimer with RapidShot, the delay value is used between each repetition. [13] 0 PRIMARY_SKIP For ShotTimer with RapidShot, use the primary delay value only before the first count (exposure). [26:14] 0 SECOND_DELAY Number of fields to delay before the next secondary count (exposure) starts. For ShotTimer with RapidShot, the delay value is used between each repetition. [27] 0 SECOND_SKIP For ShotTimer with RapidShot, use the secondary delay value only before the first count (exposure). 0x73 [2:0] 0 VD GP1_PROTOCOL Selects protocol for each general-purpose signal. [5:3] 0 GP2_PROTOCOL 0 = idle. [8:6] 0 GP3_PROTOCOL 1 = no counter association. Use MANUAL_TRIG bits to enable each GP signal. [11:9] 0 GP4_PROTOCOL 2 = test use only. [14:12] 0 GP5_PROTOCOL 3 = test use only. [17:15] 0 GP6_PROTOCOL 4 = link to mode counter. [20:18] 0 GP7_PROTOCOL 5 = link to primary counter. [23:21] 0 GP8_PROTOCOL 6 = link to secondary counter. 7 = keep on. 0x74 [12:0] 0 VD SGMASK_NUM Exposure duration (number of fields to mask SG) for LS operation. [25:13] 0 VD/SG SUBCKMASK_NUM Exposure + readout duration (number of fields to mask SUBCK) for LS. [26] 0x01 VD/SG SUBCKTOG_UPDATE 0 = SUBCK HP toggles and the registers involved in SUBCK masking (Register 0x78 and Register 0x74, Bits[27:13]) are updated at SG line. 1 = updated at update line (VD updated). [27] 0 VD/SG SUBCKMASK_SKIP1 Skip the SUBCK mask for the first exposure field only. 0x75 [0] 0 VD/SG Test Test purpose only. Must be set to 0. [13:1] 0 SUBCKSUPPRESS Number of lines after VSG line to begin SUBCK pulses. [26:14] 0 SUBCKNUM Number of SUBCK pulses per field. Must be set less than VDLEN. [27] 0 SG_SUPPRESS Suppress the SG and allow SUBCK to finish at SUBCKNUM. 0x76 [0] 0 VD/SG SUBCK_POL SUBCK start polarity. [1] 0 TESTMODE Test use only. Must be set to 0. 0x77 [13:0] 0 VD/SG SUBCK_TOG1 SUBCK Toggle Position 1. [27:14] 0 SUBCK_TOG2 SUBCK Toggle Position 2. 0x78 [13:0] 0 VD/SG SUBCKHP_TOG1 High precision SUBCK Toggle Position 1. [27:14] 0 SUBCKHP_TOG2 High precision SUBCK Toggle Position 2. 0x79 [25:0] 0 VD TESTMODE Test use only. Must be set to 0. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |