| Electronic Components Datasheet Search |
|
CS43L36 Datasheet(PDF) 43 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS43L36 Datasheet(HTML) 43 Page - Cirrus Logic |
|
43 / 89 page ![]() DS1081F3 43 CS43L36 4.9 Power-Supply Considerations Table 4-11 describes the plug/unplug status. 4.9 Power-Supply Considerations Because some power supply combinations can produce unwanted system behavior, note the following: • Control-port transactions can occur 1 ms after VP, VD_FILT, VCP, and VL exceed the minimum operating voltage. • If VP supply is off, it is recommended that all other supplies are also off. VP must be the first supply turned on. • RESET must be asserted until VP is valid. • If VD_FILT is supplied externally (DIGLDO_PDN = GND), VL must be supplied before VD_FILT, VA, VL, and VCP can come up in any order. Due to the VD_FILT POR, VD_FILT must be turned off before VA, VL, or VCP are turned off; otherwise, current could be drawn from supplies that remain on. Table 4-12 shows the maximum current for each supply when VP is on, but other supplies are on or off (all clocks are off and all registers are set to default values, i.e., reset). Table 4-13 shows requirements and available features for valid power-supply configurations. 4.9.1 VP Monitor The CS43L36 voltage comparator monitors the VP power supply for potential brown-out conditions due to power-supply overload or other fault conditions. To perform according to specifications, VP is expected to remain above 3.0 V at all times. The VP monitor is enabled by setting VPMON_PDNB (see p. 63). Fig. 4-25 shows the behavior of the VP monitor. Figure 4-25. VP Monitor Table 4-11. Tip Plug/Unplug Status Plug Status Unplug Status Interpretation 0 0 Tip is fully unplugged/not present 10 Reserved 0 1 Tip connection is in a transitional state 1 1 Tip is fully plugged/present Table 4-12. Typical Leakage Current during Nonoperational Supply States (with VP Powered On) Supply Current (µA) Notes VCP VA VL IVp IVCP IVA IVL Off On Off 14 0 0 0 VA may source or sink current Off On On 25 0 0 328 VA may source or sink current On Off Off 14 0 0 0 — On Off On 25 0 0 328 — On On Off 14 0 0 0 VA may source or sink current On On On 25 0 0 328 — Notes: • Values shown reflect typical voltage and temperature. Leakage current may vary by orders of magnitude across the maximum and minimum recommended operating supply voltages and temperatures listed in Table 3-2. • Test conditions: Clock/data lines are held low, RESET is held high, and all registers are set to their default values. Table 4-13. Valid Power-Supply Configurations Configuration Notes On: VP Off: VD_FILT = VCP = VL = VA Limited set of headset plug-detect and WAKE output features, see Section 4.7 and Section 4.8. On: VP = VL Off: VD_FILT = VCP = VA = OFF Limited set of headset plug-detect and WAKE output features, see Section 4.7 and Section 4.8. Digital I/O ESD diodes are powered to prevent conduction in pin-sharing applications. On: VP = VD_FILT = VCP = VL = VA Full chip functionality VPMON_TRIP 2.6 V 3.0 V 3.6 V |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |