| Electronic Components Datasheet Search |
|
V62/12615-01XE-R Datasheet(PDF) 83 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
V62/12615-01XE-R Datasheet(HTML) 83 Page - Texas Instruments |
|
83 / 92 page ![]() DP83848-EP www.ti.com SLLSEC6D – SEPTEMBER 2012 – REVISED JUNE 2013 9.3.11 CD Test and BIST Extensions Register (CDCTRL1) Table 9-22. CD Test and BIST Extensions Register (CDCTRL1), Address 0x1B BIT BIT NAME DEFAULT DESCRIPTION BIST ERROR Counter: BIST_ERROR_CO Counts number of errored data nibbles during Packet BIST. This value 15:8 0, RO UNT will reset when Packet BIST is restarted. The counter sticks when it reaches its max count. 7:6 RESERVED 0, RW RESERVED: Must be zero Packet BIST Continuous Mode: Allows continuous pseudo random data transmission without any break in transmission. This can be used for transmit VOD testing. This 5 BIST_CONT_MOD E 0, RW is used in conjunction with the BIST controls in the PHYCR Register (0x19h). For 10Mb operation, jabber function must be disabled, bit 0 of the 10BTSCR (0x1Ah), JABBER_DIS = 1. CD Pattern Enable for 10Mb: 4 CDPATTEN_10 0, RW 1 = Enabled 0 = Disabled 3 RESERVED 0, RW RESERVED: Must be zero Defines gap between data or NLP test sequences: 2 10MEG_PATT_GA P 0, RW 1 = 15 μs 0 = 10 μs CD Pattern Select[1:0]: If CDPATTEN_10 = 1: 00 = Data, EOP0 sequence 1:0 CDPATTSEL[1:0] 00, RW 01 = Data, EOP1 sequence 10 = NLPs 11 = Constant Manchester 1s (10MHz sine wave) for harmonic distortion testing 9.3.12 Energy Detect Control (EDCR) Table 9-23. Energy Detect Control (EDCR), Address 0x1D BIT BIT NAME DEFAULT DESCRIPTION Energy Detect Enable: Allow Energy Detect Mode. 15 ED_EN 0, RW When Energy Detect is enabled and Auto-Negotiation is disabled via the BMCR register, Auto-MDIX should be disabled via the PHYCR register. Energy Detect Automatic Power Up: Automatically begin power up sequence when Energy Detect Data 14 ED_AUTO_UP 1, RW Threshold value (EDCR[3:0]) is reached. Alternatively, device could be powered up manually using the ED_MAN bit (ECDR[12]). Energy Detect Automatic Power Down: Automatically begin power down sequence when no energy is 13 ED_AUTO_DOWN 1, RW detected. Alternatively, device could be powered down using the ED_MAN bit (EDCR[12]). Energy Detect Manual Power Up/Down: Begin power up/down sequence when this bit is asserted. When set, the Energy Detect algorithm will initiate a change of Energy Detect 12 ED_MAN 0, RW/SC state regardless of threshold (error or data) and timer values. In managed applications, this bit can be set after clearing the Energy Detect interrupt to control the timing of changing the power state. Copyright © 2012–2013, Texas Instruments Incorporated REGISTER BLOCK 83 Submit Documentation Feedback Product Folder Links: DP83848-EP |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |